Operation Temp 40℃ 〜 120℃  Manual reset type.
Resetting by button
Auto reset less than -0℃
Temp Tolerance Standards:±3~10℃ ※Depend on Operation Temp
Max Ambient Temp 120℃
Resistance between Terminals

61P :Less than 10mΩ(Initial value)

61N・61C :Less than 30mΩ (Initial value)

Insulation Resistance Not less than 1,000MΩ/DC500V
Dielectric strength Not less than AC1,500V/1min.
Not less than AC1,800V/1sec
Endurance More than 1,000cycles (Standards)

03型フェノールケース

            ※Compliance with RoHS Directives.
            ※Splash proof equivalent to IP64.
            ※Please feel free to ask us in case that operation temp, Diffential, Temp Tolerance is not standard.